Compact RDMS
TM
Telemetry Receiver
45 Quasonix, Inc.
14 Appendix E – Factory Reset Values
When a reset command is activated, the frequency defaults to the lowest valid frequency for the lowest authorized
band on the unit. The reset priority is:
1. QPSK
2. PCM/FM
3. SOQPSK
4. Multi-h CPM
Reset values for each mode are listed in the following tables.
Table 11: QPSK Factory Reset Values
Parameter Reset State
Bit Rate 1
Modulation Scaling N/A
Clock Polarity Normal
Data Polarity Normal
Derandomizer Disabled
Differential Decoder N/A
IF Filter Auto
Downconvert Antenna Disabled
AGC Enabled
Convolutional Decoder Disabled
Lock Output Polarity Active High
NRZ Encoding NRZ-L
Output Control Default
Output Muting Disabled
Phase Noise Compensation Disabled
Tape Output Disabled